Volt Polska AGM battery 12V 200Ah VRLA
Description
AGM battery 12V 200Ah VRLA
The AGM 12V 200Ah VRLA battery is designed primarily for use in backup power systems such as UPS units and automation systems. It performs best in buffer (standby) power applications, providing stable, maintenance-free operation.
Key Features
-
AGM construction with fiberglass separators that securely absorb the electrolyte.
-
Automatic pressure-regulated sealing system – safety valves release excess internal gas during overcharge, preventing damage.
-
Durable ABS housing and copper cells ensure longevity, mechanical resistance, and overall reliability.
Typical Applications
-
Emergency power systems (UPS, automation systems)
-
Alarm systems
-
Access control systems
-
Telecommunications equipment
-
Medical equipment
-
Scooters and mopeds
Why choose an AGM battery?
-
Maintenance-free – no need to refill or replace electrolyte
-
Can operate in any position
-
High efficiency and performance
-
Excellent resistance to mechanical damage and high temperatures
-
Safe operation – no electrolyte leakage
Important Notice
AGM batteries (AGM, AGM OPTI, AGM VPRO series) are not recommended for cyclic PV (solar) installations, as cyclic charging can accelerate loss of capacity and performance. These batteries are designed for standby/buffer operation, such as UPS backup systems.
Incorrect charging current settings may damage the battery and void the warranty.
Technical Specifications
| Parameter | Value |
|---|---|
| Nominal voltage | 12V |
| Nominal capacity | 200Ah |
| Internal resistance (25°C) | 3.2mΩ |
| Capacity at 40°C | 102% |
| Capacity at 25°C | 100% |
| Capacity at 0°C | 85% |
| Capacity at -15°C | 65% |
| Self-discharge (25°C, 3 months) | 91% |
| Self-discharge (25°C, 6 months) | 82% |
| Self-discharge (25°C, 12 months) | 64% |
| Recommended operating temperature | 25°C ± 3°C |
| Discharge temperature range | -15°C to 50°C |
| Charging temperature range | -10°C to 50°C |
| Storage temperature range | -20°C to 50°C |
| Charging voltage (25°C) | 14.4V (NORM) – 14.7V (BOOST) |
| Maximum charging current | 52.5A |
| Maximum discharge current | 1800A (5 seconds) |
| Design life (25°C) | 3–5 years |
| Total height | 226 mm |
| Height | 221 mm |
| Width | 240 mm |
| Length | 552 mm |
| Weight | 49 kg ± 3% |
Parameters
| Battery Mode | Buffer operation |
| Size | 226 × 240× 552mm |
| Voltage | 12V |
| Manufacturer | VoltPolska |
| Lenght | 226mm |
| Capacity | 200 Ah |
| Storage | External warehouse |
| Width | 240 |
| Saru type | M8 |
| Weight | 49000 g |
| Designed capacity | 3-5 év |
| Battery type | AGM |
| Height | 552 |